IEC DC ACB and Switch Disconnector

IEC DC ACB and Switch Disconnector

The Susol DC Air Circuit Breaker (ACB) is designed for 1500 V DC systems such as UPS, photovoltaic, and energy storage applications. Engineered for the arc characteristics of DC circuits, the high-capacity units provide reliable interrupting performance for demanding DC power systems. With intelligent trip relay functions for protection, metering, and diagnostics, along with flexible installation configurations, the Susol DC ACB supports stable and efficient power system operation.


Rated Voltage
1000 – 1500 V DC
Rated Current
800 – 4000 A
Breaking Capacity
Up to 70 kA

Key Features

01

Dedicated DC Protection and Metering

Multi-functional DC trip relay provides precise metering for current, voltage, and power, along with a range of protective functions.

02

Enhanced User Convenience

Self-diagnostics, fault event records, and waveform storage support fast fault analysis and troubleshooting.

03

Operator-Friendly Structure

An isolator structure provides convenient operation during dielectric withstand testing.

04

Environmental Application Options

Short busbar options are available to support applications where temperature performance is a consideration.

Reach out to our dedicated specialist for technical inquiries and product support.

Send an Inquiry

Lineup

Susol DC ACB

Frame Type Max. Operational Voltage(Ue) Ampere Frame Breaking Capacity Applicable Standard

E

ADH 1200 Vdc (4P) / 750 Vdc (3P) 1600, 2500, 3200, 4000 AF 35 kA@1200 Vdc(4P)
60 kA@ 500 Vdc(3P)
IEC60947-2
ADH 1200 Vdc (4P) / 750 Vdc (3P) 1600, 2500, 3200, 4000 AF 40 kA@1200 Vdc(4P)
85 kA@ 500 Vdc(3P)
IEC60947-2
ADV 1500 Vdc (4P) / 1000 Vdc (3P) 1600, 2500, 3200, 4000 AF 50 kA@1500 Vdc(4P)
60 kA@ 750 Vdc(3P)
IEC60947-2
ADV 1500 Vdc (4P) / 1000 Vdc (3P) 1600, 2500, 3200, 4000 AF 60 kA@1500 Vdc(4P)
70 kA@ 750 Vdc(3P)
IEC60947-2

Susol DC DSU

Frame Type Max. Operational Voltage(Ue) Ampere Frame Rated Short-time Withstand Current (Icw) Applicable Standard

D

DDH 1200 Vdc (4P) / 750 Vdc (3P) 800, 1000, 1250, 1600, 2000 AF 100 kA/1 s IEC 60947-3
DDV 1500 Vdc (4P) / 1000 Vdc (3P) 800, 1000, 1250, 1600, 2000, 2500 AF 100 kA/1 s IEC 60947-3

E

DDU 750 Vdc (2P) 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000, 5000, 6300 AF 100 kA/1 s IEC 60947-3
DDH 1200 Vdc (4P) / 750 Vdc (3P) 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000 AF 150 kA/1 s IEC 60947-3
DDV 1500 Vdc (4P) / 1000 Vdc (3P) 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000 AF 150 kA/1 s IEC 60947-3
DDX 1800 Vdc (4P) / 1000 Vdc (3P) 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000 AF 100 kA/1 s IEC 60947-3
DDZ 2500 Vdc (4P) 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000AF 100 kA/1 s IEC 60947-3

G

DDH 1200 Vdc (4P) / 750 Vdc (3P) 4000, 5000, 6300, 7000 AF 150 kA/1 s IEC 60947-3
DDV 1500 Vdc (4P) / 1000 Vdc (3P) 4000, 5000, 6300, 7000 AF 150 kA/1 s IEC 60947-3

Downloads

Showing 1-2 of 2 results

Catalogs

[DC ACB]

  • [DC_ACB]_EN_C06022-08-202606.pdf (56.13MB)
Catalogs

[DC Compact DSU] up to 1500Vdc

  • [DC_Compact_DSU]_up_to_1500Vdc_EN_C06012-01-202405.pdf (56.13MB)

Markets

Discover how our real-time monitoring and precise control capabilities drive operational efficiency, ensure compliance,
and maintain 24/7 continuity across the most demanding global markets.

Consult with an LS ELECTRIC Expert

Have a general question not related to quotes or technical service? Leave us a message and our team will get back to you.